The Smart LAN Support Software supports the following error codes:
- 0103
- Failed to register with protocol manager.
-
The protocol module has failed to register with the Protocol Manager. Check the PROTOCOL.INI file
configuration.
- 0104
-
- Invalid keyword.
-
There is an invalid keyword in the PROTOCOL.INI file. Check your keyword settings in your PROTOCOL.INI file.
- 0105
-
- Duplicate keyword.
-
There is a duplicate keyword in your PROTOCOL.INI file. Check your PROTOCOL.INI file configuration.
- 0106
-
- Invalid value for keyword.
-
You have assigned an invalid value to a keyword in your PROTOCOL.INI file.
- 0108
-
- Modules bindings keyword not specified.
-
Check your PROTOCOL.INI file to make sure that you have correctly bound the protocol stacks using the keyword BINDINGS.
- 1001
-
- Hardware problem: failed to bring up adapter.
-
Either the Ringnode is faulty, or no Ringnode is present.
- 1002
-
- Hardware problem: failed to discover interrupt number.
-
The Ringnode's interrupt setting may conflict with that of another device installed in the computer. Check the interrupt and I/O location settings.
- 1003
-
- Hardware problem: no adapter at specified address.
-
No adapter has been found at the expected I/O location. Either no Ringnode is present or the Ringnode is failing to respond correctly.
- 1004
-
- No network adapter is installed, or an adapter is missing.
-
No adapter has been found at the expected I/O location. Either no Ringnode is present or the Ringnode is failing to respond correctly.
- 1005
- Hardware problem: invalid IRQ number.
-
The Ringnode's interrupt setting may conflict with that of another device installed in the computer. Check the interrupt and I/O location settings.
- 1008
-
- Hardware problem: failed to download code to ad 0
-
Software was not successfully downloaded to the Ringnode. Possibly, this is because the Ringnode is not a Madge Smart 16/4 Ringnode or has insufficient memory.
- 1101
-
- No Madge Token Ring MAC modules in PROTOCOL.INI file.
-
Check that the PROTOCOL.INI file is correctly configured.
- 1103
-
- No functioning adapter found.
-
The adapter is not plugged in properly.
- 1104
-
- NDIS prints an appropriate error message when this error occurs
-
This error code usually arises when a keyword in PROTOCOL.INI causes some NDIS parameter to exceed its range. The system provides more information when this error occurs.
- 1113
-
- Hardware problem: initialize timed out.
-
The attempted Direct Memory Access, performed while initializing the adapter, timed out. There may be an incorrect DMA setting. (If this message appears during remote booting of OS/2 from LAN Server, it may indicate an interrupt clash.)
- 1114
-
- Hardware problem: check cable is attached.
-
Check that the cable is attached.
- 1127
-
- Madge Smart Ringnode Memory is full.
-
The adapter may not be a Madge Smart 16/4 Ringnode.
- 1139
-
- Adapter failed to open
-
The system provides more information when this error occurs. For example, "No network adapter installed".
- 2123
-
- Failed to define MIF.
-
The NetBIOS Define MIF call failed.
- 2401
-
- Failed to register NetBIOS
-
The NetBIOS failed to register with the arbitrator. There may already be a NetBIOS registered with the arbitrator.
- 2403
-
- IPX interface already installed.
-
There is already an IPX interface on the computer. A new one cannot be loaded unless this interface is removed.
- 2701
-
- Invalid slot in NET.CFG.
-
There is no Madge Smart 16/4 Ringnode at the slot you specified.
- 2702
-
- Invalid DMA in NET.CFG.
-
The Ringnode cannot use the DMA channel you specified. Check your NET.CFG settings for SLOT, PORT, DMA, and IRQ.
- 2703
-
- Invalid IRQ in NET.CFG.
-
The Ringnode cannot use the interrupt level you specified. Check your NET.CFG settings for SLOT, PORT, DMA, and IRQ.
- 2704
-
- Can not open MDGDOS??.BIN.
-
The MADGEODI driver cannot find the firmware file MDGDOS??.BIN. Put in the same directory as MADGEODI.COM.
- 3216
-
- Misplaced section heading.
-
The parser was not expecting a section heading here.
- 3217
-
- Misplaced data.
-
There is a mistake in your SMART.CFG file, or on the command line.
- 3222
-
- Unable to find protocol.
-
The parser cant find the named protocol, either in the executable file created by SMTLINK, or on the disk in the path. Try changing the PATH= parameter.
- 3223
-
- Module version is incompatible.
-
Specified protocol modules are incompatible. Be sure to have versions that are compatible.
- 3224
-
- Unrecognized keyword.
-
The Smart II Software does not recognize the specified keyword; check the spelling, or that the keyword is in the appropriate protocol section.
- 3225
-
- Unrecognized data.
-
The data given in the SMART.CFG file, or on the command-line, could not be recognized by the parser.
- 3229
-
- String is too long, maximum length is...
-
You have used a word that is too long. The maximum possible length of the word is given.
- 3230
-
- Keyword requires data.
-
A keyword was given but the necessary data was not present.
- 3232
-
- Too many instances of . Maximum is...
-
You have attempted to load too many instances of a Smart module. The maximum instances are:
4 for LLC, NDIS, and ODI
2 for NetBIOS
1 for IPX and TCP/IP
- 3233
-
- No protocols installed.
-
No protocols have been installed, due to an earlier error. This can be caused by a problem with the adapter.
- 3234
-
- Insufficient memory space on adapter.
-
There is not sufficient memory space on the adapter to download all the protocols specified.
- 3238
-
- Failed to register LLC.
-
The LLC failed to register with the arbitrator.
- 3240
-
- LSL not loaded.
-
No LSL has been loaded so ODI cannot be loaded.
- 3243
-
- Smart ODI internal error.
-
A serious internal error has occurred with the ODI protocol module. Fatal, cannot continue.
- (NO CODE)
-
- External file: no further information available.
-
An error occurred parsing NET.CFG.
- 3250
-
- Bad IP address
-
You have specified an incorrect IP address.
- 3251
-
- Router not on local network
-
The default router is not on the same IP network as the host.
- 3252
-
- Specified ip.netmask not suitable for Class A network
-
The IP address you have specified is for a Class A network, but the net mask is not suitable for a Class A network.
- 3256
-
- failed to set ip.address
-
The Smart II Software cannot discover your host's IP address.
- 9900
-
- Specified adapter card cannot be found
- .
The adapter specified in the SMART.CFG file cannot be found.
- 9905
-
- Unable to allocate memory for buffers.
-
There is insufficient memory for receive and/or transmit buffers.
- 9980
-
- Receive/transmit buffer too small for maximum frame size.
-
The receive or transmit buffer size is less than the maximum frame size.
![[Using Madge Wizard]](../../graphics/bk_mdgw.gif)
![[Ringnode Installation]](../../graphics/bk_hw.gif)
![[Driver Installation]](../../graphics/bk_sw.gif)
![[Software Utilities]](../../graphics/bk_cfg.gif)